Start-up
45
animal. Block the area next to the feeding station, if neces-
sary.
If an antenna identifies two animals simultaneously, animal iden-
tification will be disrupted for both animals.
> The distance between two antennas should be approx. 100
cm, in order to avoid overlaps of the identification range. In
case of double or foreign identifications, you have to screen
the antennas by means of grounded plates.
3.6.2
Connecting the antenna cable to the motherboard
Only
service personnel
is allowed to connect the antenna
cables.
1. Remove the casing cover of the control unit.
Caution
: Lay out the antenna cables in such a way that
they are not damaged by the animals.
4
1
3
2
1 Cable of the hand-held terminal
3 Antenna cable of feeding station 2
2 Antenna cable of feeding station 1
4 Cable clamps
Danger!
Hazardous voltage! Electric shock
hazard.
Pull the mains plug.