Start-up
51
1.
>
device data
>
portion
>
tol. conc.
2.
>
device data
>
portion
>
tol. milk
3. In
tol. milk
enter the desired value and confirm with
.
4. In
tol. conc.
enter the desired value and confirm with
.
3.10
Vapour screen for powder outlet, mixer heating and equipment against frost
The heating element located at the milk powder outlet (vapor
screen) prevents condensation.
Mixer jar heating prevents residual feed from cooling down.
Tolerance for:
Concentration
Mik ratio
Default value:
± 20 g/L
± 20 %
Range:
± 0 to 50 g/L
± 0 to 100 %
Example:
For an animal the feed concentration is 120 g/L.
For another animal the feed concentration is 110 g/L. If the
default setting for the tolerance value of the concentration
(±20 g/L) is maintained, this animal is allowed to drink to-
gether with the already drinking animal: The difference be-
tween the concentration value of the prepared feed (120 g/
L) and the concentration value for the animal according to
its feeding plan (110 g/L) is less than the set tolerance val-
ue (±20 g/L).
Whereas, if the tolerance value had been 0 g/L, the animal
– like for the priority mode – would have been fed only after
the animal drinking first had consumed its complete portion.
portion
...
tol. conc.: ±[20]g/L
tol. milk: ± 20 %
portion
...
tol. conc.: ± 20 g/L
tol. milk: ±[20]%
Summary of Contents for TAK5-CH1-25
Page 38: ...38 Operation ...
Page 54: ...54 Start up ...
Page 70: ...70 Setup ...
Page 84: ...84 Device data ...
Page 90: ...90 Calibration ...
Page 150: ...150 Cleaning ...
Page 170: ...170 Animal control ...
Page 192: ...192 Failures and warnings ...
Page 196: ...196 Care and maintenance plan Routine tasks ...
Page 215: ......
Page 218: ...218 Annex 16 3 5 Template for individual feeding plan ...
Page 219: ...Annex 219 16 4 Basic principle of interval feeding ...
Page 222: ...222 Annex ...