7 Connection
7.1 FLUXUS *601
FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
58
For the configuration of an output see section 13.1.
Fig. 7.9:
Connection of the adapter for the active current input
1 – input adapter
2 – adapter for the active current input
3 – connector
4 – passive current source
Tab. 7.4:
Circuit of the output when connecting an active input
output
transmitter
external circuit
remark
internal circuit
connection
active current
output
R
ext
< 900
Ω
U
int
= 24 V DC
CH A
COMM
Output
P3...P8
P2
P1
T1/T3
T2/T4
Input
CH B
DC-IN
1
T1
T3
3
2
+ -
passive current source
+
-
Px+
Px-
+
-
mA