17 Advanced functions
17.6 Uncorrected flow velocity
FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
156
• Enter the cut-off flow.
• Press ENTER.
All negative values of the flow velocity greater than this limit will be set to zero.
If
Cut-off Flow\absolut
and
user
are selected, only one value have to be entered:
• Enter the cut-off flow.
• Press ENTER.
The absolute value of all flow velocity values lower than this limit will be set to zero.
17.6
Uncorrected flow velocity
For special applications, the uncorrected flow velocity might be of interest.
The profile correction for the flow velocity is activated in
Special Funct.\SYSTEM
settings\Measuring\Flow Velocity
.
• Select
normal
to display and output the flow velocity with profile correction.
• Select
uncorr.
to display and output the flow velocity without profile correction.
• Press ENTER.
If
uncorr.
is selected, each time the program branch
Measuring
is selected it will be
requested whether the profile correction is to be used or not.
If
no
is selected, the profile correction will be switched off. All physical quantities will be
calculated with the uncorrected flow velocity.
During the measurement, the designation of the physical quantity is displayed in capital
letters to indicate that the value is uncorrected.
• Press ENTER.
Special Funct.\...\-Cut-off Flow
Special Funct.\...\Cut-off Flow
Special Funct.\SYSTEM settings\Measuring\Flow Velocity
A:PROFILE CORR.
>NO<
yes
A:FLOW VELOCITY
2.60
m/s