7 Connection
7.1 FLUXUS *601
FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
50
Charging the battery
Connect the power supply to the transmitter, see section 7.1.2.2. Switch on the transmit-
ter. The charging starts automatically. The LED "BATTERY" flashes green while
charging. The max. charging time is approx. 8 h.
During the charging process, the ambient temperature should be in the range of
0...45 °C.
A measurement can be made during the charging. Charging will be stopped automatical-
ly when the battery is fully charged. The LED "BATTERY" lights green then.
Storage of the battery
The battery remains in the transmitter. After storage, the transmitter can immediately be
operated with the battery.
• battery charge: > 30 %
• storing temperature: 12...25 °C
Maintenance (relearn cycle)
The accuracy of the displayed value for the charge state of the battery is improved by ex-
ecuting a relearn cycle. The ambient temperature during a relearn cycle should be in the
range of 12...30 °C.
• Select
Special Funct.\Battery status
.
• Press ENTER.
The charge state of the battery is displayed (here: 73 %).
A question mark (
?
) and
RELEARN
indicate that the value for the displayed battery charge
is not reliable. A relearn cycle is recommended.
Proceed as follows for a relearn cycle:
• Charge the battery completely. The LED "BATTERY" lights green when charging is fin-
ished.
• Discharge the battery completely: Remove the power supply unit from the transmitter.
In order to deactivate the automatic power-off during discharging, start a measurement.
Discharging takes min. 14 h. The LED "BATTERY" will flash red afterwards.
Notice!
The battery will only be charged if the transmitter is switched on.
Special Funct.\Battery status
■■■■■
? 73‰-
RELEARN! Cy: 24