18 SuperUser mode
FLUXUS F60*
18.9 Manual reset of the totalizers
183
UMFLUXUS_F60xV5-0EN, 2017-10-16
18.9
Manual reset of the totalizers
If the manual reset of the totalizers is activated, the totalizers can be reset to zero during
the measurement by pressing key C 3 times.
• Select
Special Funct.
\
SYSTEM settings
\
Measuring
\
Miscellaneous
.
• Press ENTER until the menu item
3xC
clear totals
is displayed.
• Select
on
to activate the manual reset of the totalizers,
off
to deactivate it.
• Press ENTER.
18.10
Display of the totalizer sum
The totalizer sum of both flow directions can be displayed in the upper line during the
measurement.
• Select
Special Funct.
\
SYSTEM settings
\
Measuring
\
Miscellaneous
.
• Press ENTER until the menu item
Show
Σ
Q
is displayed.
• Select
on
to activate the display of the totalizer sum,
off
to deactivate it.
• Press ENTER.
If the display of the totalizer sum is activated, the sum
Σ
Q
of the totalizers can be dis-
played in the upper line during the measurement.
Special Funct.\SYSTEM settings\Measuring\Miscellaneous\3xC
clear totals
Notice!
The manual reset of the totalizers is still active after the deactivation of the SuperUser
mode.
Special Funct.\SYSTEM settings\Measuring\Miscellaneous\Show
Σ
Q
Fig. 18.2:
Display of the totalizer sum
Σ
Q
13.2 m3