4. Commissioning
4-22
Festo P.BE-SBO-Q-EN en 1602e
Application and function of the modes
Triggered
Testing of individual parts in stop-and-go or slow part flow.
The trigger signal is generated by a master controller or a
sensor as soon as the check part is in front of the Compact
Vision System. The inspection results are output following the
inspection, and the device then waits for the next valid trig
gering signal.
Free run
Inspection of individual or continuous parts with medium to
fast (continuous) part flow.
The trigger signal is present permanently, irrespective of
whether or not there is a check part in front of the Compact
Vision System. The device acts like a basic sensor. The
inspection results are output following the inspection. After
that, the device begins immediately with the next inspection.
Additionally, there is the possibility to set up a image trigger.
Fixed frame rate
Inspection of continuous parts at a constant speed.
The triggering signal is permanently present. The inspection
results are output following the inspection. The device starts
the next inspection in accordance with the defined frame rate.
4.9.1
I/O process in “Triggered” evaluation mode
In the “Triggered” evaluation mode, exactly one cycle is
started through a valid signal at the “Triggering Signal” input
(edge controlled). One cycle thereby includes the image
evaluation and output of results.
Triggering signals are valid only under the following conditions:
–
Output “Ready for Operation” signals logic 1
and
–
any time period set since output “Ready for operation” =
logic 1 has expired.
This setting is made over the system parameter
“Ignore triggering signal after ready for operation”.
Summary of Contents for SBO***-Q Series
Page 2: ......
Page 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Page 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Page 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Page 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Page 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Page 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Page 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Page 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Page 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...