4. Commissioning
4-94
Festo P.BE-SBO-Q-EN en 1602e
Enter slave features manually
When an EDS
file is installed, the following information about
the EtherNet/IP slave is added to the EDS library.
Basic information
Value
Description
Vendor name
Festo
Manufacturer
Vendor ID
26
Manufacturer ID
Device Type
0
Generic device
Product code
21314
Product code
Major version/Minor version
3.5
Version/revision
Input size/output size
32 bit/16 bit
Size of the cyclically transmitted I/O data
Device Type
SBOx Q
Device type
Extended Ethernet/IP
slave features
Value
Description
Request Packet Interval (RPI)
15 ms
Minimum cycle time
Exclusive Owner connections
1
Number of direct connections permitted.
(Only one controller may connect with the
device.)
Input only connections
0 (not supported)
Used for devices without outputs – not
relevant here.
Listen only connections
3
Requires an existing “Exclusive Owner
connection”. Up to three devices can “listen”,
e.g. for purposes of visualisation on a display.
Summary of Contents for SBO***-Q Series
Page 2: ......
Page 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Page 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Page 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Page 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Page 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Page 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Page 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Page 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Page 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...