3. Installation
3-12
Festo P.BE-SBO-Q-EN en 1602e
Connection
Type
Designation
Description
Connection via
hub or switch
SBOA-K30E-M12S
Cable
Ethernet cable for simple demands
1)
– Straight socket, M12, 4-pin, d-coded
– RJ-45 Ethernet plug
– 3 m long
Direct connection
with the PC
SBOA-K30E-M12S
Cable
–
Coupling
Cable coupling for RJ45 plug connector
2)
–
Cable
Ethernet cross link
2)
1)
The Ethernet cable SBOA-K30E-M12S has been designed for short-term use as a diagnostic cable
or for continuous use as a fixed cable for simple demands.
2)
Only required if the network connection of the PC does not support automatic adaptation of the
send and receive cables (AUTO MDI-X). This accessory is available from dealers.
Tab. 3/5:
Cables for the SBO Compact Vision System
For special use in an industrial environment use a screened
flexible Ethernet round cable of category 5 which will fulfil
your requirements as regards resistance to oil, bending
radius, permitted bending cycles etc.
Connections: M12 socket, 4-pin d-coded and RJ45 plug
Cables and plug connectors for special requirements are
available from dealers,
e.g. Franz Binder GmbH & Co. (product series 825) or
from HARTING Electronics GmbH & Co. KG (product series
Harax
®
M12 or Harting RJ Industrial
®
).
Ethernet connection
Via the Ethernet interface, the connection can be created to
the PC and displays or higher-level controllers. To permit a
connection, several prerequisites with regard to the devices
network address and the PC must be met (
è
The network characteristics of the device can be adjusted
using the SBO-DeviceManager (
è
For data exchange via EasyIP, Telnet or other protocols, relev
ant system parameters must be selected (
è
Summary of Contents for SBO***-Q Series
Page 2: ......
Page 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Page 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Page 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Page 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Page 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Page 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Page 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Page 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Page 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...