4. Commissioning
4-85
Festo P.BE-SBO-Q-EN en 1602e
Note
Use only integers when writing values to flag word
addresses.
RFW
Read FlagWord
RFW <address
>
Outputs the current value of the specified flag word address as
text
(
è
Only 1 address can be read out in each case using the Telnet
XML function.
Fig. 4/27: Reading out the flagword address
If the operation is successful, the result will appear
in the fol
lowing format:
<Camera>
<DataResult_RFW>RESULT VALUE
</DataResult_RFW>
</Camera>
RNV – Read Named Value
RNV [name of feature]
RNV “Name of feature”
Ouputs the current feature value of the specified feature
name (
è
Only 1 feature value can be read out in each case using the
Telnet XML function..