4. Commissioning
4-49
Festo P.BE-SBO-Q-EN en 1602e
“Acknowledge Error signal” input
If an error status occurs in the device, logic 1 is displayed at
the “Error status” output. Additionally, the “Ready for opera
tion” output switches to logic 0.
Incoming trigger signals are not valid, that is, no more
evaluations are possible until the error has been corrected.
The error must be corrected through appropriate measures
while the system remains in error status. Diagnosis can be
conducted and system parameters changed during this time.
For this, use CheckKon or all protocols that can access
system parameters.
As soon as the error has been corrected, this must be
notified to the Compact Vision System via the “Acknowledge
Error signal” input. The “Acknowledge Error signal” is edge-
controlled detected.
If a warning condition is signaled (e.g. at the “Warning”
output), this does not need to be acknowledged with the
Acknowledge Error signal. The warning condition is automat
ically lifted when the cause is eliminated.
Information on the errors (description and recommendations
for remedy) can be found in chapter 5.1.2.
Summary of Contents for SBO***-Q Series
Page 2: ......
Page 19: ...System overview 1 1 Festo P BE SBO Q EN en 1602e Chapter 1 System overview...
Page 39: ...Mounting 2 1 Festo P BE SBO Q EN en 1602e Chapter 2 Mounting...
Page 47: ...Installation 3 1 Festo P BE SBO Q EN en 1602e Chapter 3 Installation...
Page 62: ...3 Installation 3 16 Festo P BE SBO Q EN en 1602e...
Page 63: ...Commissioning 4 1 Festo P BE SBO Q EN en 1602e Chapter 4 Commissioning...
Page 162: ...4 Commissioning 4 100 Festo P BE SBO Q EN en 1602e Fig 4 34 Structure of an imported data type...
Page 183: ...Technical appendix A 1 Festo P BE SBO Q EN en 1602e Appendix A Technical appendix...
Page 247: ...Index B 1 Festo P BE SBO Q EN en 1602e Appendix B Index...
Page 248: ...B Index B 2 Festo P BE SBO Q EN en 1602e Table of contents B Index B 1...