Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
95
The error 02-0 is activated through modification of the error response. Reactions causing the drive to
stop are returned as ON, all others as OFF. When overwriting with 0, the error response WARNING is
set; when overwriting with 1, the error response CONTROLLER ENABLE OFF.
Object 6510
h
_40
h
: nominal_current
The device nominal current
can be read with the object nominal_current. It is simultaneously the upper
limit value that can be written into the object 6075
h
(motor_rated_current).
Sub-Index
40
h
Description
nominal_current
Data Type
UINT32
Access
ro
PDO mapping
no
Units
mA
Value Range
–
Default Value
device-dependent
Other values may be displayed due to a power derating, dependent on the controller cycle
time and the output stage clock frequency.
Object 6510
h
_41
h
: peak_current
The device peak current can be read with the object peak_current. It is simultaneously the upper limit
value, which can be written into the object 6073
h
(max_current).
Sub-Index
41
h
Description
peak_current
Data Type
UINT32
Access
ro
PDO mapping
no
Units
mA
Value Range
–
Default Value
device-dependent
The values apply for a current regulator cycle time of 125 μs.
Other values may be displayed due to a power derating, dependent on the controller cycle
time and the output stage clock frequency.