![Festo CMMP-AS-***-M0 Series Manual Download Page 227](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119227.webp)
B
Diagnostic messages
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
227
Error group 5
Internal voltage supply
No.
Reaction
Message
Code
5-3
5410h
Undervoltage of digital I/O
PSoff
Cause
Overloading of the I/Os?
Faulty peripheral device?
Measure
Check connected peripherals for short circuit / rated loads.
Check connection of the brake (connected incorrectly?).
5-4
5410h
Overcurrent of digital I/O
PSoff
Cause
Overloading of the I/Os?
Faulty peripheral device?
Measure
Check connected peripherals for short circuit / rated loads.
Check connection of the brake (connected incorrectly?).
5-5
-
Module supply voltage failure
PSoff
Cause
Defect on the plugged-in interface.
Measure
Interface replacement
Repair by the manufacturer.
5-6
-
X10, [X11] and RS232 supply voltage failure
PSoff
Cause
Overloading through connected peripherals.
Measure
Check pin allocation of the connected peripherals.
Short circuit?
5-7
-
Safety module internal voltage failure
PSoff
Cause
Defect on the safety module.
Measure
Internal defect
Repair by the manufacturer.
5-8
-
Failure of Internal voltage 3 (15V)
PSoff
Cause
Defect in the motor controller.
Measure
Internal defect
Repair by the manufacturer.
5-9
-
Encoder supply defective
PSoff
Cause
Back measurement of the encoder voltage not OK.
Measure
Internal defect
Repair by the manufacturer.