5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
117
Value
Meaning
0
No limitation
1
AIN0
2
AIN1
3
AIN2
4
Fieldbus (selector B)
Object 2416
h
: speed_limitation
With the object group speed_limitation, the maximum speed of the motor can be limited in the operat
ing mode profile_torque_mode, which makes a speed-limited torque mode possible. The setpoint value
source of the limit speed is specified via the object limit_speed_input_channel. Here, a choice can be
made between specification of a direct setpoint value (fixed value) or specification via an analogue
input. Depending on the source chosen, either the limit torque (fixed value) or the scaling factor for the
analogue inputs (source = analogue input) is specified via the object limit_speed. In the first case, the
limit is at the specified speed; in the second case, the speed is specified that should correspond to a
present voltage of 10 V.
Index
2416
h
Name
speed_limitation
Object Code
RECORD
No. of Elements
2
Sub-Index
01
h
Description
limit_speed_input_channel
Data Type
UINT8
Access
rw
PDO mapping
no
Units
–
Value Range
0 … 4
Default Value
0
Sub-Index
02
h
Description
limit_speed
Data Type
INT32
Access
rw
PDO mapping
no
Units
speed units
Value Range
–
Default Value
–