![Festo CMMP-AS-***-M0 Series Manual Download Page 161](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119161.webp)
6
Device Control
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
161
Bit
Value
Function
0
0001
h
Status of the motor controller (
(These bits must be evaluated together.)
1
0002
h
2
0004
h
3
0008
h
4
0010
h
voltage_enabled
5
0020
h
Status of the motor controller (
6
0040
h
7
0080
h
warning
8
0100
h
drive_is_moving
9
0200
h
remote
10
0400
h
target_reached
11
0800
h
internal_limit_active
12
1000
h
set_point_acknowledge/speed_0/homing_attained/ip_mode_active
13
2000
h
following_error/homing_error
14
4000
h
manufacturer_statusbit
15
8000
h
Drive referenced
Tab. 6.7
Bit allocation in the status word
All bits of the statusword are unbuffered. They represent the current device status.
Besides the motor controller status, various events are displayed in the statusword, i.e. a specific
event, such as following error, is assigned to each bit. The individual bits have the following significance
thereby:
statusword
Bit
Function
Description
4
voltage_enabled
This bit is set when the output stage transistors are switched on.
If bit 7 is set in the object 6510
h
_F0
h
(compatibility_control),
(
chap. 5.2) the following applies:
This bit is set if the output stage transistors are switched on.
Tab. 6.8
statusword bit 4
Warning
In case of a defect, the motor can still be powered.