![Festo CMMP-AS-***-M0 Series Manual Download Page 266](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119266.webp)
B
Diagnostic messages
266
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Error group 58
Error during communication / parameterisation (only CMMP-AS-...-M3)
No.
Reaction
Message
Code
58-1
-
General error parameterisation
configurable
Cause
Parameterisation session for more than 8 h active.
The safety module aborted the parameterisation session.
The error message is stored in the diagnostic memory.
Measure
Finish the parameterisation session before the 8 h limit or
break and restart the session.
58-4
80E9h
Buffer internal communication
configurable
Cause
–
Communication connection faulty.
–
Timeout / data error / incorrect sequence (packet counter) in
data transmission between the basic unit and safety module.
–
Too much data traffic, new requests are being sent to safety
module before old ones have been responded to.
Measure
Check communication interfaces, wiring, screening, etc.
Check whether other devices have read access to the motor
controller and safety module during a parameterisation session
- this may overload the communication connection.
Check whether the firmware versions of the safety module and
basic unit and the versions of the FCT plugin and SafetyTool are
compatible.
58-5
80EAh
Communication safety module - base unit
configurable
Cause
–
Packet counter error during transmission μC1 <-
μC2.
–
Checksum error during transmission μC1 <-
μC2.
Measure
Internal malfunction in the motor controller.
Check whether the firmware versions of the safety module and
basic unit and the versions of the FCT plugin and SafetyTool are
compatible.