![Festo CMMP-AS-***-M0 Series Manual Download Page 215](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119215.webp)
7
Operating modes
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
215
Object 6074
h
: torque_demand_value
By means of this object, the current nominal torque can be read out in thousands of the nominal torque
(6076
h
). The internal limitations of the controller (current limit values and I
2
t monitoring) are hereby
taken into account.
Index
6074
h
Name
torque_demand_value
Object Code
VAR
Data Type
INT16
Access
ro
PDO mapping
yes
Units
motor_rated_torque/1000
Value Range
--
Default Value
--
Object 6076
h
: motor_rated_torque
This object specifies the nominal torque of the motor. This can be taken from the motor's name plate. It
is entered in the unit 0.001 Nm.
Index
6076
h
Name
motor_rated_torque
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
yes
Units
0.001 mNm
Value Range
–
Default Value
296
Object 6077
h
: torque_actual_value
By means of this object, the motor's actual torque can be read out in thousanths of the nominal torque
(object 6076
h
).
Index
6077
h
Name
torque_actual_value
Object Code
VAR
Data Type
INT16