5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
113
Object 6068
h
: position_window_time
If the actual position of the drive is located within the positioning window (position_window) for as long
as defined in this object, the related bit 10 target_reached is set in the status word.
Index
6068
h
Name
position_window_time
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
ms
Value Range
–
Default Value
0
Object 6510
h
_22
h
: position_error_switch_off_limit
In the object position_error_switch_off_limit, the maximum tolerance between the setpoint and actual
position can be entered. In contrast to the above contouring error message, if exceeded the output
stage is immediately switched off and an error triggered. The motor thus runs out unbraked (unless a
holding brake is on hand).
Index
6510
h
Name
drive_data
Object Code
RECORD
No. of Elements
51
Sub-Index
22
h
Description
position_error_switch_off_limit
Data Type
UINT32
Access
rw
PDO mapping
no
Units
position units
Value Range
0 … 2
32
-1
Default Value
0
Value
Meaning
0
Contouring error limit value OFF (reaction: NO ACTION)
0
Contouring error limit value ON (reaction: SWITCH OUTPUT STAGE OFF IMMEDIATELY)
The error 17-0 is activated through modification of the error response. The reaction SWITCH OUTPUT
STAGE OFF IMMEDIATELY is returned as ON, all others as OFF. When overwriting with 0, the error re
sponse NO ACTION is set; when overwriting with a value greater than 0, the error response SWITCH
OUTPUT STAGE OFF IMMEDIATELY is set.