6
Device Control
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
155
Status diagram: status transitions
The following table lists all statuses and their meaning:
No.
Is performed when
Bit combination (controlword)
Action
Bit
3 2 1 0
0
0
Switched on or reset occurs
Internal transition
Perform self-test
1
Self-test successful
Internal transition
Activation of CAN
communication
2
Output stage and controller
enable prev. + command
Shutdown
Shutdown
x
1 1 0 –
3
Command Switch On
Switch On
x
1 1 1
Switching on the output
stage
4
Command Enable Operation
Enable Operation
1 1 1 1
Control in accordance with
set operating mode
5
Command Disable
Operation
Disable Operation
0 1 1 1
Output stage is blocked.
Motor rotates freely.
6
Command Shutdown
Shutdown
x
1 1 0
Output stage is blocked.
Motor rotates freely.
7
Command Quick Stop
Quick Stop
x
0 1 x
–
8
Command Shutdown
Shutdown
x
1 1 0
Output stage is blocked.
Motor rotates freely.
9
Command Disable Voltage
Disable Voltage
x
x
0 x
Output stage is blocked.
Motor rotates freely.
aJ
Command Disable Voltage
Disable Voltage
x
x
0 x
Output stage is blocked.
Motor rotates freely.
aA
Command Quick Stop
Quick Stop
x
0 1 x
Braking is initiated in
accordance with
quick_stop_option_code.
aB
Braking ended without
command Disable Voltage
Disable Voltage
x
x
0 x
Output stage is blocked.
Motor rotates freely.
aC
Error occurred
Internal transition
For uncritical errors, reaction
in accordance with
fault_reaction_option_code.
With critical errors, transition
aD
follows
aD
Error handling is ended
Internal transition
Output stage is blocked.
Motor rotates freely.
aE
Error elim Fault
Reset command
Fault Reset
Bit 7 =
0
1
Acknowledge error
(with rising edge)