6
Device Control
164
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Sub-Index
00
h
Description
manufacturer_statuswords
Data Type
UINT8
Access
ro
PDO Mapping
no
Units
–
Value Range
–
Default Value
1
Sub-Index
01
h
Description
manufacturer_statusword_1
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
–
Value Range
–
Default Value
–
manufacturer_statusword_1
Bit
Signal
Description
Bit 0
IS_REFERENCED
Drive is referenced
Bit 1
COMMUTATION_
VALID
Commutation valid
Bit 2
READY_FOR_ENABLE
The bit is set if all conditions to enable the controller are
present and only the controller enable itself is lacking. The
following conditions must be present:
–
The drive is error free.
–
The intermediate circuit is loaded.
–
Angle encoder analysis is ready. No processes (e.g. serial
transmission) are active that prevent enabling.
–
No blocking process is active (e.g. the automatic motor
parameter identification).
–
STO is not active or a safety function is active, which per
mits enabling.
Bit 3
IPO_IN_TARGET
Positioning generator has completed the profile.
Bit 4 ... 7
CAM
Reserved and used for the cam.
Bit 8
SAFE_STANDSTILL
“Safe Stop” “H” on the 7-segment display.
Use by safety module CAMC-G-S1.
Bit 9 ... 11
–
Reserved for extensions.