![Festo CMMP-AS-***-M0 Series Manual Download Page 151](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119151.webp)
6
Device Control
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
151
6.1.2
Status diagram of the motor controller (state machine)
SWITCH_ON_DISABLED
READY_TO_SWITCH_ON
FAULT_REACTION_ACTIVE
FAULT
SWITCH_ON
OPERATION_ENABLE
QUICK_STOP_ACTIVE
NOT_READY_TO_SWITCH_ON
1
0
0
2
7
aJ
3
6
8
9
aC
aD
aE
aB
aA
Power enabled
(output stage on)
Fault
(error)
Power disabled
(output stage off )
4
5
Fig. 6.1