![Festo CMMP-AS-***-M0 Series Manual Download Page 114](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119114.webp)
5
Setting parameters
114
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 607B
h
: position_range_limit
The object group position_range_limit includes two sub-parameters that limit the numeric range of the
position values. If one of these limits is exceeded, the position actual value automatically jumps to the
other limit. This permits parametrisation of so-called round axes. To be specified are the limits that
should correspond physically to the same position, for example 0° and 360°.
For these limits to become effective, a round axis must be selected via the object 6510
h
_20
h
(position_range_limit_enable).
Index
607B
h
Name
position_range_limit
Object Code
ARRAY
No. of Elements
2
Data Type
INT32
Sub-Index
01
h
Description
min_position_range_limit
Access
rw
PDO mapping
yes
Units
position units
Value Range
–
Default Value
–
Sub-Index
02
h
Description
max_position_range_limit
Access
rw
PDO mapping
yes
Units
position units
Value Range
–
Default Value
–
Object 6510
h
_20
h
: position_range_limit_enable
Through the object position_range_limit_enable, the range limits defined through the object 607B
h
can
be activated. Various modes are possible:
If the mode “shortest path” is selected, positioning is always executed along the physically shortest
distance. To do this, the drive adapts to the prefix of the travel speed. In both “fixed direction of rota
tion” modes, positioning only takes place in the direction specified in the mode.