7.3.2
Description of the objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
607A
h
VAR
target_position
INT32
rw
6081
h
VAR
profile_velocity
UINT32
rw
6082
h
VAR
end_velocity
UINT32
rw
6083
h
VAR
profile_acceleration
UINT32
rw
6084
h
VAR
profile_deceleration
UINT32
rw
6085
h
VAR
quick_stop_deceleration
UINT32
rw
6086
h
VAR
motion_profile_type
INT16
rw
Affected objects from other chapters
Index
Object
Name
Type
Chapter
6040
h
VAR
controlword
INT16
6 Device control
6041
h
VAR
statusword
UINT16
6 Device control
605A
h
VAR
quick_stop_option_code
INT16
6 Device control
607E
h
VAR
polarity
UINT8
6093
h
ARRAY
position_factor
UINT32
6094
h
ARRAY
velocity_encoder_factor
UINT32
6097
h
ARRAY
acceleration_factor
UINT32
Object 607A
h
: target_position
The object target_position (target position) determines which position of the motor controller should
be traveled to. The current setting for speed, acceleration, brake delay and type of travel profile
(motion_profile_type) etc. must be considered thereby. The target position (target_position) is inter
preted either as an absolute or relative specification (controlword, bit 6).
Index
607A
h
Name
target_position
Object Code
VAR
Data Type
INT32
Access
rw
PDO mapping
yes
Units
position units
Value Range
–
Default Value
0