![Festo CMMP-AS-***-M0 Series Manual Download Page 138](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119138.webp)
5
Setting parameters
138
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Sub-Index
01
h
Description
sample_mode
Data Type
UINT16
Access
rw
PDO mapping
no
Units
–
Value Range
0 … 1,
table
Default Value
0
Value
Measurement file
0
Continuous sampling
1
Autolock sampling
The following object displays a new sample event.
Sub-Index
02
h
Description
sample_status
Data Type
UINT8
Access
ro
PDO mapping
yes
Units
–
Value Range
0 … 3,
table
Default Value
0
Bit
Value
Name
Description
0
01
h
falling_edge_occurred
= 1: New sample position (falling edge)
1
02
h
rising_edge_occurred
= 1: New sample position (rising edge)
The bits of the object sample_status can be established with the following object, which should also
result in setting bit 15 of the status word. Through this, the information “sample event occurred” is
available in the status word, which will normally be transmitted anyway, so the controller has to read
the object sample_status only to determine which edge has occurred, if applicable.
Sub-Index
03
h
Description
sample_status_mask
Data Type
UINT8
Access
rw
PDO mapping
yes
Units
–
Value Range
0 … 1,
table
Default Value
0