Diagnostic messages
276
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Error group 80
IRQ overflow
No.
Reaction
Message
Code
80-1
F081h
Overflow speed controller IRQ
PSoff
Cause
The process data could not be calculated in the set current/speed/
position interpolator cycle.
Measure
Please contact Technical Support.
80-2
F082h
Overflow position controller IRQ
PSoff
Cause
The process data could not be calculated in the set current/speed/
position interpolator cycle.
Measure
Please contact Technical Support.
80-3
F083h
Overflow interpolator IRQ
PSoff
Cause
The process data could not be calculated in the set current/speed/
position interpolator cycle.
Measure
Please contact Technical Support.
Error group 81
IRQ overflow
No.
Code
Message
Reaction
81-4
F084h
Overflow low-level IRQ
PSoff
Cause
The process data could not be calculated in the set current/speed/
position interpolator cycle.
Measure
Please contact Technical Support.
81-5
F085h
Overflow MDC IRQ
PSoff
Cause
The process data could not be calculated in the set current/speed/
position interpolator cycle.
Measure
Please contact Technical Support.
Error group 82
Internal sequence control
No.
Code
Message
Reaction
82-0
-
Internal sequencing control: Event
configurable
Cause
IRQ4 overflow (10 ms low-level IRQ).
Measure
Internal sequence control: Process was interrupted.
For information only - no action required.
82-1
-
Multiple-started KO write access
configurable
Cause
Parameters in cyclical and acyclical operation are used concur
rently.
Measure
Only one parameterisation interface can be used (USB or Ether
net).