5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
93
Object 6510
h
_32
h
: max_power_stage_temperature
The temperature of the output stage can be read via the object 6510h_31h
(power_stage_temperature). If the temperature specified in the object max_power_stage_temperature
is exceeded, the output stage shuts off and an error message is output.
Sub-Index
32
h
Description
max_power_stage_temperature
Data Type
INT16
Access
ro
PDO mapping
no
Units
°C
Value Range
100
Default Value
device-dependent
Object 6510
h
_33
h
: nominal_dc_link_circuit_voltage
Through the object nominal_dc_link_circuit_voltage, the nominal device voltage can be read in milli
volt.
Sub-Index
33
h
Description
nominal_dc_link_circuit_voltage
Data Type
UINT32
Access
ro
PDO mapping
no
Units
mV
Value Range
–
Default Value
device-dependent
Object 6510
h
_34
h
: actual_dc_link_circuit_voltage
Via the object actual_dc_link_circuit_voltage, the current voltage of the intermediate circuit can be
read in millivolts.
Sub-Index
34
h
Description
actual_dc_link_circuit_voltage
Data Type
UINT32
Access
ro
PDO mapping
yes
Units
mV
Value Range
–
Default Value
–