Error group 52
Safety function
No.
Reaction
Message
Code
52-2
809Ah
Safety function: Failure of driver supply with active PWM con
trol
PSoff
Cause
This error message does not occur with devices delivered from the
factory. It can occur with use of a user-specific device firmware.
Measure
The safe status was requested with enabled power output
stage. Check inclusion in the safety-oriented interface.
52-3
809Bh
Safety module: Overlapping velocity limits in basic unit
PSoff
Cause
–
Basic unit reports error if the currently requested direction of
movement is not possible because the safety module has
blocked the setpoint value in this direction.
Measure
Error may occur in connection with the SSF if an asymmetrical
speed window is used where one limit is set to zero.
In this case, the error occurs when the basic unit moves in the
"blocked" direction in the Positioning mode.
Check application and change if necessary.
Error group 53
Violation of Safety conditions (only CMMP-AS-...-M3)
No.
Code
Message
Reaction
53-0
80A1h
USF0: Safety condition violated
configurable
Cause
–
Violation of monitored speed limits of the SSF0 in operation /
when USF0 / SSF0 requested.
Measure
Check when the violation of the safety condition occurs:
a) During dynamic braking to the safe speed
b) After the drive has reached the safe speed.
With a) Critical check of braking ramp record trace - can the
drive follow the ramp?
Change parameters for the braking ramp or start time / delay
times for monitoring.
With b) Check how far the current speed is from the monitored
limit speed; increase distance if necessary (parameter in safety
module) or correct speed specified by controller.
53-1
80A2h
USF1: Safety condition violated
configurable
Cause
–
Violation of monitored speed limits of the SSF1 in operation /
when USF1 / SSF1 requested.
Measure
See USF0, error 53-0.
53-2
80A3h
USF2: Safety condition violated
configurable
Cause
–
Violation of monitored speed limits of the SSF2 in operation /
when USF2 / SSF2 requested.
Measure
See USF0, error 53-0.