Error group 68
EtherNet/IP (only CMMP-AS-...-M3)
No.
Reaction
Message
Code
68-3
-
EtherNet/IP: Connection aborted
configurable
Cause
A connection interruption occurred during operation.
Measure
Check the cabling between the motor controller and the higher-
level control system.
Establish a new connection to the control system.
68-4
-
EtherNet/IP: Duplicate network address
configurable
Cause
At least one device with the same IP address exists in the network.
Measure
Use unique IP addresses for all devices in the network.
Error group 69
EtherNet/IP (only CMMP-AS-...-M3)
No.
Code
Message
Reaction
69-0
-
EtherNet/IP: Minor fault
configurable
Cause
A minor error was detected in the EtherNet/IP interface.
Measure
Try to acknowledge the error.
Carry out a reset.
69-1
-
EtherNet/IP: Incorrect IP configuration
configurable
Cause
An incorrect IP configuration has been detected.
Measure
Correct the IP configuration.
69-2
-
EtherNet/IP: Field bus module not found
configurable
Cause
There is no EtherNet/IP interface in the slot.
Measure
Please check whether an EtherNet/IP interface is in slot Ext2.
69-3
-
EtherNet/IP: Module version not supported
configurable
Cause
There is an EtherNet/IP interface with incompatible version in the
slot.
Measure
Carry out a firmware update to the most up-to-date motor con
troller firmware.
Error group 70
FHPP protocol
No.
Code
Message
Reaction
70-1
-
FHPP: Mathematical error
configurable
Cause
Overrun/underrun or division by zero during calculation of cyclic
data.
Measure
Check the cyclic data.
Check the factor group.
70-2
-
FHPP: Factor group invalid
configurable
Cause
Calculation of the factor group leads to invalid values.
Measure