![Festo CMMP-AS-***-M0 Series Manual Download Page 115](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119115.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
115
Index
6510
h
Name
drive_data
Object Code
RECORD
No. of Elements
51
Sub-Index
20
h
Description
position_range_limit_enable
Data Type
UINT16
Access
rw
PDO mapping
no
Units
–
Value Range
0 … 5
Default Value
0
Value
Meaning
0
Off
1
Shortest path (for compatibility reasons)
2
Shortest distance
3
Reserved
4
Fixed direction of rotation “positive”
5
Fixed direction of rotation, “negative”
Object 2030
h
: set_position_absolute
Through the object set_position_absolute, the readable actual position can be displaced without chan
ging the physical position. The drive does not make any movement.
If an absolute encoder system is connected, the position shift is stored in the encoder if the encoder
system permits it. The position shift thus remains intact even after a reset. This storage operation runs
in the background independently of this object. All parameters belonging to the encoder storage are
saved with their current values.
Index
2030
h
Name
set_position_absolute
Object Code
VAR
Data Type
INT32
Access
wo
PDO mapping
no
Units
position units
Value Range
–
Default Value
–