![Festo CMMP-AS-***-M0 Series Manual Download Page 208](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119208.webp)
7
Operating modes
208
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 606F
h
: velocity_threshold
The object velocity_threshold specifies from which actual speed value the drive is considered to be
standing still. If the drive exceeds the speed value specified here for a specific time period, bit 12
(velocity = 0) is deleted in the statusword. The time period is determined through the object
velocity_threshold_time.
Index
606F
h
Name
velocity_threshold
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
speed units
Value Range
0 … 65536 min
-1
Default Value
10
Object 6070
h
: velocity_threshold_time
The object velocity_threshold_time specifies how long the drive may exceed the specified speed before
bit 12 (velocity = 0) is deleted in the statusword.
Index
6070
h
Name
velocity_threshold_time
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
ms
Value Range
0 … 4999
Default Value
0