Rev. I
OS and Drivers
4-59
MR Series Technical Reference Manual
❏
[Averaging]
This samples plural values of touch position data and averages them. The default setting is
0. If it is set higher, the program will ignore minute movements of the finger.
Note:
If the Averaging value is too high, the following of the cursor is not good and sometimes the cursor may fly
to an unexpected location.
❏
[Low pass filter]
This can filter and ignore the data containing jitters, noise and unusual data. The default
setting is 0 and the Low pass filter feature is off.
Note:
When making the value of the Low pass filter high, the following of the mouse cursor becomes bad.
❏
[Use liftoff packet]
When the User liftoff packet checkbox is clicked, the touch panel recognizes when the finger
leaves the touch panel immediately regardless of the setting value of the Lift off time.
❏
[Packets]
This item is not supported.
❏
[Defaults]
This returns each setting to the default.
Advanced
The following screen is displayed if the Advanced tab is clicked.
The management of the touching position data and the setting of the beep sounds.
❏
[Advanced settings for]
Select the touch panel device name to set. Generally, the “Device 1" is selected.
Summary of Contents for DM-M820