6 Operation
Wellenlötanlage CIG highspeed SIG
DOK-002
6-14
Fig. 6-7: "POP UP FLAPS/PPM" window
1. Enter a value for the minimum residual oxygen content in the
M
IN
field (1).
2. Enter a value for the maximum residual oxygen content in the
M
AX
field (2).
►
If the residual oxygen content in the machine is too high or too low,
this can result in damage to the solder material or the machine.
Block the machine input to prevent damage.
1. If you would like the machine input to be blocked when the residual
oxygen content is too low, touch
C
LOSE
(3).
2. If you would like the machine input to be blocked when the residual
oxygen content is too high, touch
C
LOSE
(4).
►
An emergency off can be triggered by the following events:
- You have activated the "Stop" operating mode.
- A serious error has occurred in the machine.
- The power supply has been interrupted.
How to control the residual oxygen content
The residual oxygen content inside the machine is controlled
automatically according to the values that have been entered.
How to block the machine input
The machine input is blocked. Printed circuit boards and frames
cannot enter the machine.
How to power up the machine again after an emergency off