6 Operation
Wellenlötanlage CIG highspeed SIG
DOK-002
6-46
a If you would like the machine to continue production in spite of an
error message, activate
S
TART
(3).
b If you would like the machine to complete all jobs in the system in
spite of an error message, activate
E
MPTY
(4).
c If you would like the machine to stop immediately, activate
S
TOP
(5).
►
The selected option turns green.
►
Touch
B
ACK
to discard your changes.
"POP UP PREHEATING" window
It is possible to set the following parameters for the preheating in use in
the "POP UP PREHEATING" window:
●
Number of switching points used in the system controls
●
Number of preheating radiators connected to the switching point
●
Zone length of preheating zones 1 and 2
Fig. 6-34: "POP UP PREHEATING" window
1. Touch
N
UMBER OF SWITCHING POINTS
(1) and enter the number of
switching points.
2. Touch
L
AMPS PER SWITCHING POINT
(2) and enter the number of lamps.
3. Touch
2
ND ZONE STARTS FROM SWITCHING POINT
(3) and enter the zone
length.
"Extended settings" window
The error message has been created.
How to set preheating parameters
The parameters have been set.
2
1
3