4-39
Vertical Alt Main Screen
From the Move Machine step, you can review the angular and offset alignment
conditions. Refer to the Angular Move section on page 4-39 and Offset Move sec-
tion on page 4-41 for more information. If an alignment correction requires a live
move, this can also be done from this step. Refer to the Vertical Live Move section
on page 3-150 for more information.
Angular Move
From the Angular Move screen, you can review the angular alignment condition.
Angular Move Screen
The amount of movement at the machine flange (expressed in either mils or mil-
limeters (mm), depending on the analyzer units) is displayed in the table just to the
right of the flange. Emerson recommends that the flange bolts be loosened and
the shims be added (or removed) as suggested in the table. When correcting
angular misalignment keep the flange offset movement to a minimum. After shim-
ming is complete, re-tighten the flange bolts and take a new set of readings.