3-109
Laser Address Selection
Note
A maximum of 20 reading sets (moves) can be stored on an align-
ment job. If more than 20 reading sets are acquired a message dis-
plays which provides the option to either discard the last reading set
taken or overwrite the 20th reading set with the last reading.
Acquiring Manual 4 Point Data
If the laser heads can only be rotated to three of the cardinal positions, the fourth
will be automatically calculated when Enter is pressed and after the third reading
has been acquired. Using only three readings increases the likelihood of error and
does not allow the instrument to check data validity. Emerson does not recom-
mend using only three readings if four are available.
Clear All key
Use the Clear All key to clear all the data stored at each of the cardinal positions at
any time.