3-96
Horizontal Alignment
Averaging Mode
The Averaging mode of operation is intended to allow multiple sampling of data
in order to reduce the noise in the data by averaging all of the acquired values. In
this mode of operation, the last 20 readings are averaged.
Starting Manual Sweep
On the data acquisition screen for Manual Sweep, the current laser reading (in mils
or mm, depending on the analyzer units) for each laser head is displayed in reverse
video just below the corresponding machine. The current laser head positions
(represented by a hash mark on the outer most part of the circles) are displayed
graphically at the bottom of the screen. The angle reading will be displayed within
the circle. The background of the circles will be white if the laser heads are not
within 2° of each other and green when the laser heads are within 2° of each other.