3-70
Horizontal Alignment
Change Sensor Location key
Use the Change Sensor Location key, when the coupling is selected (highlighted
with the red box around it), to change the side of the coupling on which the target
dial indicator readings are to be taken. The sensor location determines the direc-
tion (sign) of the Rim TIR (Total Indicator Runout). For example, if the left
machine was to be set 3 mils high, then if the sensor location was specified to be on
the left machine shaft and the top target reading was 0.0, the bottom reading would
be -6.0 mils. With the same conditions and the sensor specified to be on the right
machine shaft, the bottom reading would be +6.0 mils.
Enter key
Use the Enter key to advance to the Enter Face/Rim Target screen.
Enter Face/Rim Target
The Enter Face/Rim Target screen, allows you to enter the target face and rim dial
indicator readings.