3-116
Horizontal Alignment
Note
For the Auto Sweep and Dual Pass methods, if the laser heads have
not yet been initialized and they have not been turned off since they
acquired the last set of data, the data stored in the heads can be trans-
ferred to the analyzer without having to re-sweep the laser heads. This
is done using the Resend Data option on Alt Laser Configuration
screen. This is useful if for some reason the data transfer from the
heads to the analyzer was aborted before it was complete.
Note
For the greatest accuracy and repeatability, all readings should be
acquired using the same direction of rotation. In addition, it is best to
rotate the laser heads in the same direction the machine rotates when
running.
The 8215/8225 laser fixtures are designed to be rotated a full revolution in two sec-
onds. As with any sweep, a smooth, uniform acceleration and deceleration during
the rotation of the laser heads is necessary for accurate, reliable, and repeatable
data.
Caution!
To prevent damage to the laser heads, make sure the antennas do not come into
contact with obstacles (e.g. the ground or base plate) as they are being rotated.
Also, when performing an uncoupled alignment and the laser heads are
mounted in close proximity to each other, make sure the antennas do not come
into contact with each other as one laser head is rotated past the other.
The typical method of operation will be for the user to initialize the laser heads with the ana-
lyzer. One of the heads will then be moved to a new position. Then the second head will be
moved past the first head to a new position. As the laser heads pass each other, the data will
be acquired. The first head will then be moved past the second head to a new position.
Again, as the laser heads pass each other, both laser heads will acquire the data. This method
continues until the user has acquired the necessary number of passes and downloads the
data to the analyzer. This may include several full rotations of the laser heads.
Summary of Contents for 2130 RBM Consultant Pro
Page 6: ...vi ...
Page 20: ...1 8 Fixtures Case Layout top section ...
Page 90: ...3 10 Horizontal Alignment ...
Page 364: ...5 22 Straightness Measurements ...