3-176
Horizontal Alignment
This option is available by selecting the Align C-face Machine option after viewing
the tolerance plot(s) for a Quick Spec job. Refer to the Quick Spec section on page
3-53 for more information.
C-Face setup screen
The C-face Setup screen allows you to enter the dimensions for the flange location
where moves are to be made.
Note
This section assumes that the fixtures are set up to the point that the
laser heads are mounted.
Dimensions can be expressed in either inches or millimeters (mm), depending on
the analyzer units. All dimensions must be entered before continuing. The range
of values that can be entered for the A dimension is -3600 to 3600 inches or -91440
to 91440 mm. The range of values that can be entered for the Y dimension is 1.0 to
1000 inches or 25.4 to 25400 mm. The Y Dimension default is 1 inch (25.4 mm).
Summary of Contents for 2130 RBM Consultant Pro
Page 6: ...vi ...
Page 20: ...1 8 Fixtures Case Layout top section ...
Page 90: ...3 10 Horizontal Alignment ...
Page 364: ...5 22 Straightness Measurements ...