1592015820 User manual IC260_261L_D DUO FW1.9 rel. 1.0
Pag. 134 of 149
US 36
Analog output 2 summer minimum set point
-30.0
-22
0.0
0
US38
°C
°F
Bar
Psi
Dec
int
Dec
int
US 37
Analog output 2 summer maximum set point
US38
70.0
158
50.0
725
°C
°F
Bar
Psi
Dec
int
Dec
int
US 38
Analog output 2 summer set point
US36
US37
°C
°F
Bar
Psi
Dec
int
Dec
int
US 39
Analog output 2 winter minimum set point
-30.0
-22
0.0
0
US41
°C
°F
Bar
Psi
Dec
int
Dec
int
US 40
Analog output 2 winter maximum set point
US41
70.0
158
50.0
725
°C
°F
Bar
Psi
Dec
int
Dec
int
US 41
Analog output 2 winter set point
US39
US40
°C
°F
Bar
Psi
Dec
int
Dec
int
US 42
Analog output 2 summer differential
0.0
0
0.0
0
25.0
45
14.0
203
°C
°F
Bar
Psi
Dec
int
Dec
int
US 43
Analog output 2 winter differential
0.0
0
0.0
0
25.0
45
14.0
203
°C
°F
Bar
Psi
Dec
int
Dec
int
US 44
Analog output 2 minimum value
0
US45
%
US 45
Analog output 2 maximum value
US44
100
%
US 46
Operation mode under minimum value
0
1
Modulating evaporator water pump
US 47
Probe 1 selection for evaporator water pump modulation in chiller
0
10
US 48
Probe 2 selection for evaporator water pump modulation in chiller
0
10
US 49
Set point for maximum speed of modulationg evaporator water pump in chiller
30.0
-58
0.0
0
70.0
158
50.0
725
°C
°F
Bar
Psi
Dec
int
Dec
int
US 50
Proportional band for maximum speed of modulationg evaporator water pump in chiller
0.0
0
0.0
0
25.0
45
14.0
203
°C
°F
Bar
Psi
Dec
int
Dec
int
US 51
Minimum speed of the evaporator water pump in chiller
0
100
%
US 52
Maximum speed of the evaporator water pump in chiller
0
100
%
US 53
Probe 1 selection for evaporator water pump modulation in Heat Pump
0
10
US 54
Probe 2 selection for evaporator water pump modulation in Heat Pump
0
10
US 55
Set point for maximum speed of modulationg evaporator water pump in Heat Pump
30.0
-58
0.0
0
70.0
158
50.0
725
°C
°F
Bar
Psi
Dec
int
Dec
int
US 56
Proportional band for maximum speed of modulationg evaporator water pump in Heat
Pump
0.0
0
0.0
0
25.0
45
14.0
203
°C
°F
Bar
Psi
Dec
int
Dec
int
US 57
Minimum speed of the evaporator water pump in Heat Pump
0
100
%
US 58
Maximum speed of the evaporator water pump in Heat Pump
0
100
%
US 59
Speed of the water pump in Free Cooling
0
100
%
US 60
Speed of the water pump when compressor OFF
0
100
%
AUX output enable
US 61
AUX 1 relay operation mode
1= only in Chiller
2= only in Heat pump
3= in Chiller and Heat pump
1
3
US 62
AUX 2 relay operation mode
1= only in Chiller
2= only in Heat pump
3= in Chiller and Heat pump
US 63
AUX 1 analog output operation mode
1= only in Chiller
2= only in Heat pump
3= in Chiller and Heat pump
US 64
AUX 2 analog output operation mode
1= only in Chiller
2= only in Heat pump
3= in Chiller and Heat pump
Condenser fan
Parameters
Description
min
max
M. U.
Resolution