Pro Tools Reference Guide
794
SMPTE Trigger while Locking to an Unresolved
Source
SMPTE Trigger can be used with an optional
SYNC peripheral or equivalent device to resolve
Pro Tools recording and playback speed while
slaving to LTC. This enables long-term, accurate
synchronization by resolving to any variations
in incoming time code. SYNC peripherals also
support VITC and Bi-phase/Tach positional ref-
erence.
SYNC Peripheral Synchronization
Options
By adding a Digidesign SYNC peripheral to your
Pro Tools|HD system, you can use Pro Tools as
the master device in your synchronization
setup. All other devices are then slaved to
Pro Tools.
You can use Pro Tools in conjunction with a
SYNC peripheral to generate LTC, MIDI Time
Code, or MMC commands. When the SYNC pe-
ripheral is reading incoming SMPTE time code,
it regenerates the time code through the LTC or
MTC output connector. This signal can be
passed along to other slave devices.
MachineControl™
Digidesign SYNC peripherals also support
Digidesign MachineControl software, which
provides many specialized features for post-pro-
duction synchronization tasks including remote
track arming, VTR emulation, serial time code,
and other capabilities. (See the
MachineControl
Guide
for more information, or contact your
Digidesign dealer.)
Ext. Clock Output
Pro Tools can be used as the master device in
your synchronization setup, where all other de-
vices are then slaved to Pro Tools word clock
output.
With Pro Tools|HD systems, clock output can be
configured for 1x word clock, or 256x Slave
Clock for Digidesign Legacy I/Os (such as 888|24
I/O). See the
Pro Tools|HD Getting Started Guide
for more information on clock output and Leg-
acy I/Os.
To set Ext. Clock Output:
1
Choose Setup > Hardware in Pro Tools.
2
Click the Ext. Clock Output pop-up menu and
select an available signal.
3
Click OK to close the Hardware Setup dialog
when you have finished.
For instructions on connecting an external
synchronization peripheral to your Pro Tools
system, refer to your Getting Started Guide.
If you are using a SYNC peripheral, refer to
its documentation.
If the Legacy Port is enabled (as opposed to
the Expansion Port) then the Ext. Clock
Output automatically switches to
Slave256x. To reset the Ext. Clock Output,
the Port Settings button must be set back to
Expansion and the Legacy I/O must be set to
No Interface. (To set a Legacy I/O to No In-
terface, select its name in the Peripherals
list, then choose No Interface from the
Interface pop-up menu.)
Summary of Contents for Pro Tools
Page 1: ...Pro Tools Reference Guide Version 7 3 ...
Page 15: ...1 Part I Introduction ...
Page 16: ...2 ...
Page 33: ...19 Part II System Configuration ...
Page 34: ...20 ...
Page 44: ...Pro Tools Reference Guide 30 ...
Page 94: ...Pro Tools Reference Guide 80 ...
Page 95: ...81 Part III Sessions Tracks ...
Page 96: ...82 ...
Page 108: ...Pro Tools Reference Guide 94 ...
Page 130: ...Pro Tools Reference Guide 116 ...
Page 269: ...255 Part IV Recording ...
Page 270: ...256 ...
Page 310: ...Pro Tools Reference Guide 296 ...
Page 345: ...331 Part V Editing ...
Page 346: ...332 ...
Page 402: ...Pro Tools Reference Guide 388 ...
Page 496: ...Pro Tools Reference Guide 482 ...
Page 548: ...Pro Tools Reference Guide 534 ...
Page 571: ...557 Part VI MIDI Editing ...
Page 572: ...558 ...
Page 596: ...Pro Tools Reference Guide 582 ...
Page 637: ...623 Part VII Mixing ...
Page 638: ...624 ...
Page 702: ...Pro Tools Reference Guide 688 ...
Page 771: ...757 Part VIII Video Sync Surround ...
Page 772: ...758 ...
Page 792: ...Pro Tools Reference Guide 778 ...
Page 806: ...Pro Tools Reference Guide 792 ...
Page 856: ...Pro Tools Reference Guide 842 ...