Ch11 Summary of Parameter Settings | VFD-ED
11-18
Pr.
Parameter Name
Setting Range
Default
VF
VFPG
SVC
FOCPG
FOCPM
06-29 Voltage of Emergency
Power
24.0–375.0 V
DC
48.0–750.0 V
DC
24.0
48.0
○
○
○
○
○
06-30 Fault Output Setting
Method
0: According to Pr.06-22–Pr.06-25
1: According to the binary setting
0
○
○
○
○
○
06-31 Phase Loss Detection of
Drive Output at
Start-up (MPHL)
0: Disable
1: Enable
1
○
○
○
○
○
06-32 Accumulated Drive
Power-on Time at the
First Fault (min.)
0–65535 Read
only
○
○
○
○
06-33 Accumulated Drive
Power-on Time at the
First Fault (day)
0–65535 Read
only
○
○
○
○
06-34 Accumulated Drive
Power-on Time at the
Second Fault (min.)
0–65535 Read
only
○
○
○
○
06-35 Accumulated Drive
Power-on Time at the
Second Fault (day)
0–65535 Read
only
○
○
○
○
06-36 Accumulated Drive
Power-on Time at the
Third Fault (min.)
0–65535 Read
only
○
○
○
○
06-37 Accumulated Drive
Power-on Time at the
Third Fault (day)
0–65535 Read
only
○
○
○
○
06-38 Accumulated Drive
Power-on Time at the
Fourth Fault (min.)
0–65535 Read
only
○
○
○
○
06-39 Accumulated Drive
Power-on Time at the
Fourth Fault (day)
0–65535 Read
only
○
○
○
○
06-40 Accumulated Drive
Power-on Time at the
Fifth Fault (min.)
0–65535 Read
only
○
○
○
○
06-41 Accumulated Drive
Power-on Time at the
Fifth Fault (day)
0–65535 Read
only
○
○
○
○
06-42 Accumulated Drive
Power-on Time at the
Sixth Fault (min.)
0–65535 Read
only
○
○
○
○
06-43 Accumulated Drive
Power-on Time at the
Sixth Fault (day)
0–65535 Read
only
○
○
○
○
06-44 (EPS) Emergency
Power Mode Operation
Speed
0.00–400.00 Hz
Read only
○
○
○
○
○
06-45
Fault and Warning
Actions
Bit0 = 0: Display Lv fault and coast to
stop
Bit0 = 1: Display Lv warn and coast to
stop
Bit1 = 0: Fan lock, fault and coast to stop
Bit1 = 1: Fan lock, warn and coast to stop
Bit2 = 0: software GFF protection
enabled
Bit2 = 1: software GFF protection
disabled
0
○
○
○
○
○
06-46
(EPS) Emergency
Power ON Operation
Direction
0: Run according to the current command
1: Run according to the operation
direction of power generation mode,
and execute the power generation
0
○
○
○
○
○
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...
Page 389: ...Appendix B Revision History VFD ED B 16 The page intentionally left blank...