Ch11 Summary of Parameter Settings | VFD-ED
11-1
Chapter 11 Summary of Parameter Settings
This chapter provides a summary of parameter settings including the ranges and defaults that help you set the
parameters. You can set, change, and reset the parameters with the digital keypad.
NOTE
1)
: Indicates a parameter that you can set during operation.
2) For more details on parameters, refer to Chapter 12 Descriptions of Parameter Settings.
3)
◆
indicates that the parameters or the setting values only apply on the Direct Docking Mode. The actual
functions of each elevator controller vary from one to another. For more information, please contact Delta.
4) The parameters described in this user manual are designed for multi-step speed mode. The defaults for direct
docking mode are different from the defaults described in this user manual. If you need to use the direct
docking mode, contact Delta for more information.
00 Drive Parameters
: You can set this parameter during operation.
NOTE
IM: Induction Motor; PM: Permanent Magnet Motor
Pr.
Parameter Name
Setting Range
Default
VF
VFPG
SVC
FOCPG
FOCPM
00-00
AC Motor Drive Identity
Code
108: 220 V, 2.2 kW, 3 HP (single-phase)
110: 220 V, 3.7 kW, 5 HP (single-phase)
10: 230V, 4.0 kW, 5 HP
11: 460V, 4.0 kW, 5 HP
12: 230V, 5.5 kW, 7.5 HP
13: 460V, 5.5 kW, 7.5 HP
14: 230V, 7.5 kW, 10 HP
15: 460V, 7.5 kW, 10 HP
16: 230V, 11 kW, 15 HP
17: 460V, 11 kW, 15 HP
18: 230V, 15 kW, 20 HP
19: 460V, 15 kW, 20 HP
20: 230V, 18.5 kW, 25 HP
21: 460V, 18.5 kW, 25 HP
22: 230V, 22 kW, 30 HP
23: 460V, 22 kW, 30 HP
24: 230V, 30 kW, 40 HP
25: 460V, 30 kW, 40 HP
26: 230V, 37 kW, 50 HP
27: 460V, 37 kW, 50 HP
29: 460V, 45 kW, 60 HP
31: 460V, 55 kW, 75 HP
33: 460V, 75 kW, 100 HP
Read Only
○
○
○
○
○
00-01 AC Motor Drive Rated
Current Display
Display by model
Read only
○
○
○
○
○
00-02 Parameter Reset
0: No function
0
○
○
○
○
○
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...
Page 389: ...Appendix B Revision History VFD ED B 16 The page intentionally left blank...