Ch08 Specifications | VFD-ED
8-2
8-1 230V Series
Frame Size
B
C
D
E
Model VFD-_ _ _ED23/21S
022* 037* 040
055
075
110
150
185
220
300
370
Applicable Motor Output (kW)
2.2
3.7
4
5.5
7.5
11 15 18.5 22 30 37
Applicable Motor Output (HP)
3
5
5
7.5
10
15 20 25 30 40 50
Output Rating
Rated Output Capacity (kVA)
4.8
6.8
7.9
9.5
12.5
19 25 29 34 46 55
Rated Output Current (A)
12
17
20
24
30
45 58 77 87 132
161
Maximum Output Voltage (V)
Three-phase proportional to input voltage
Output Frequency Range
0.00–400 Hz
Carrier Frequency Range
2–15 kHz
2–9 kHz
Rated Output Maximum
Carrier Frequency
8 kHz
10 kHz
8 kHz
6 kHz
Input Rating
Input
Current
(A)
24 34 20 23 30 47 56 73 90 132 161
Rated Voltage (V)
One-phase Three-phase
200–240
Rated Frequency (Hz)
50/60
Voltage Tolerance
±10% (180–264 V)
Frequency Tolerance
±5% (47–63 Hz)
Cooling Method
Fan cooling
Weight
(kg)
6 6 6 8 10 10 13 13 13 36 36
*VFD022ED21S & VFD037ED21S are one-phase input models.
8-2 460V Series
Frame Size
B
C
D
E
Model VFD-_ _ _ED43S
040
055
075
110
150
185
220
300 370 450
550
750
Applicable Motor Output (kW)
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Applicable Motor Output (HP)
5
7.5
10
15
20
25
30
40
50
60
75
100
Output Rating
Rated Output Capacity (kVA) 9.2
10.4 13.5 18.3 24 30.3 36 46.2
63.7 80 96.4 116.3
Rated Output Current (A)
11.5
13
17
23
30
38
45
58
80
100
128
165
Maximum Output Voltage (V)
Three-phase proportional to input voltage
Output Frequency Range
0.00–400 Hz
Carrier Frequency Range
2–15 kHz
2–9 kHz
2–6 kHz
Rated Output Maximum
Carrier Frequency
8 kHz
10 kHz
8 kHz
6 kHz
Input Rating
Input
Current
(A)
11.5 14 17 24 30 37 47 58 80 100 128 165
Rated Voltage (V)
Three-phase 380–480
Rated Frequency (Hz)
50/60 Hz
Voltage Tolerance
±10% (342–528 V)
Frequency Tolerance
±5% (47–63 Hz)
Cooling Method
Fan cooling
Weight
(kg)
6 8 10 10 10 10 13 14.5
36 36 50 50
*Assumes operation at the rated output current. Input current rating varies depending on the input reactor,
transformer, wiring connections and power supply impedance.
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...
Page 389: ...Appendix B Revision History VFD ED B 16 The page intentionally left blank...