Ch11 Summary of Parameter Settings | VFD-ED
11-19
Pr.
Parameter Name
Setting Range
Default
VF
VFPG
SVC
FOCPG
FOCPM
direction detection when in power
generation mode.
2: After determining the power generation
direction, the host controller sends a
running direction command. (When at
STOP, the direction of power
generation mode (MO = 32) confirms
and the direction of power generation
mode does not remain.)
Execute the
power generation direction detection
every time.
3. After determining the power generation
direction, the host controller sends a
running direction command. (When at
STOP, the direction of power
generation mode (MO =32) confirms
and the direction of power generation
mode remains.)
Execute the power
generation direction detection one
time.
4. Run according to the operation
direction of power generation mode,
and execute the power generation
direction detection when in normal
mode.
06-47 Power Generation
Direction Search Time
0.0–5.0 sec.
1.0
○
○
○
○
○
06-48 Power Capacity of
Emergency Power
(EPS)
0.0–100.0 kVA
0.0
○
○
○
○
○
06-49 STO Latch Selection
0000h: STO fault latched, resending RUN
command is required
0001h: STO warning latched, resending
RUN command is required
0002h: STO fault latched
0003h: STO warning unlatched
0000h
○
○
○
○
○
06-50 MO’s Action when
Retrying after Fault
0: Output
1: No output
0
○
○
○
○
○
06-51 Number of Times to
Retry after Fault
0–10
0
○
○
○
○
○
06-52 Time Interval between
Retries
0.5–600.0 sec.
10.0
○
○
○
○
○
06-53 Frequency Command
when the Most Recent
Fault Occurred
0.00–655.35 Hz
Read only
○
○
○
○
○
06-54 Output Frequency when
the Most Recent Fault
Occurred
0.00–655.35 Hz
Read only
○
○
○
○
○
06-55 Output Current when
the Most Recent Fault
Occurred
0.00–655.35 Amps
Read only
○
○
○
○
○
06-56 Motor Frequency when
the Most Recent Fault
Occurred
0.00–655.35 Hz
Read only
○
○
○
○
○
06-57 Output Voltage when
the Most Recent Fault
0.0–6553.5 V
Read only
○
○
○
○
○
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...
Page 389: ...Appendix B Revision History VFD ED B 16 The page intentionally left blank...