11-7
02 Digital Input / Output Parameters
: You can set this parameter during operation.
Pr.
Parameter Name
Setting Range
Default
VF
VFPG
SVC
FOCPG
FOCPM
02-00 Two-wire/three-wire
Operation Control
0: FWD/STOP, REV/STOP
1: FWD/STOP, REV/STOP
(Line Start Lockout)
2: RUN/STOP, REV/FWD
3: RUN/STOP, REV/FWD
(Line Start Lockout)
4: Three-wire
5: Three-wire (Line Start Lockout)
0
○
○
○
○
○
02-01 Multi-Function
Input
Command 1 (MI1)
0: no function
1
○
○
○
○
○
(The Stop terminal for
three-wire operation)
1: multi-step speed command 1
○
○
○
○
○
02-02 Multi-Function
Input
Command 2 (MI2)
2: multi-step speed command 2
2
○
○
○
○
○
02-03 Multi-Function
Input
Command 3 (MI3)
3: multi-step speed command 3
3
○
○
○
○
○
02-04 Multi-Function
Input
Command 4 (MI4)
4: multi-step speed command 4
4
○
○
○
○
○
02-05 Multi-Function
Input
Command 5 (MI5)
5: Reset
0
○
○
○
○
○
02-06 Multi-Function
Input
Command 6 (MI6)
6: JOG command
0
○
○
○
○
○
02-07 Multi-Function
Input
Command 7 (MI7)
7: Acceleration/ deceleration speed
inhibit
0
○
○
○
○
○
02-08 Multi-Function Input
Command 8 (MI8)
(Enable Drive terminal)
8: First, second
acceleration/deceleration time
40
○
○
○
○
○
9: Third, fourth
acceleration/deceleration
time
○
○
○
○
○
10: EF input (Pr.07-28)
○
○
○
○
○
11: Reserved
12: Stop output
○
○
○
○
○
13–14:
Reserved
15: AUI1 operation speed command
○
○
○
○
○
16: Reserved
17: AUI2 operation speed command
○
○
○
○
○
18: Emergency Stop (Pr.07-28)
○
○
○
○
○
19–23:
Reserved
24: FWD JOG command
○
○
○
○
○
25: REV JOG command
○
○
○
○
○
26:
Reserved
27:
ASR1/ASR2
selection
○
○
○
○
○
28: Emergency stop (EF1)
(Motor coasts to stop)
○
○
○
○
○
29–30:
Reserved
31: High torque bias (according to
Pr.07-21)
○
○
○
○
○
32: Middle torque bias (according to
Pr.07-22)
○
○
○
○
○
33: Low torque bias (according to
Pr.07-23)
○
○
○
○
○
34–37:
Reserved
38: Disable writing to EEPROM function
○
○
○
○
○
39: Torque command direction (0 is
positive direction)
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...
Page 389: ...Appendix B Revision History VFD ED B 16 The page intentionally left blank...