Ch10 Auto-tuning Process
| VFD-ED
10-10
10-3-3 Motor Auto-tuning
10-3-3-1 Motor Settings
Pr.00-09 Control Mode
Press
Press
Mode selection:
Settings
Control
Mode
Applicable
Motor Type
Speed
Feedback
Energy-
savings
Tuning
Difficulty
Ride
Comfort
Speed
Control
Range
Motor
Parameter
Tuning
Basic
Control
Speed
Control
0 V/F IM
Low Low Normal 1:50
V/F
control
Voltage
control
1 VFPG
IM
✓
Medium Medium Normal
1:50
✓
Frequency
control
Frequency
control
2 SVC
IM
Medium
Medium
Normal 1:50
✓
Voltage
control
Voltage
control
3 FOCPG IM
✓
High High Good 1:1000
✓
Vector
control
Frequency
control
8 FOCPM PM
✓
High High Good 1:1000
✓
Vector
control
Frequency
control
Determines the AC motor drive control method.
0: You can set the V/F ratio as required and control multiple motors simultaneously.
1: You can use a PG card with an Encoder for close-loop speed control.
2: Use auto-tuning for optimal settings of the control parameters.
3: To increase torque and the accuracy of the speed control (1:1000).
8: To increase torque and the accuracy of the speed control (1:1000). This setting is for use
only with permanent magnet motors. The other settings are for use with induction motors.
Pr.01-00 Maximum Output Frequency
Press
Press
Determines the AC motor drive maximum output frequency, ranging from 5–400 Hz.
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...