Ch11 Summary of Parameter Settings | VFD-ED
11-14
05 IM Parameters
: You can set this parameter during operation.
Pr.
Parameter Name
Setting Range
Default
VF
VFPG
SVC
FOCPG
FOCPM
05-00 Motor Auto-tuning
0: No function
1: Dynamic test (Rs, Rr, Lm, Lx, no-load
current) (Motor runs)
2: Static test (Motor does not run)
0
○
05-01 Motor Rated Current
(40–120%) * Pr.00-01 Amps
#.##
○
○
○
○
05-02 Motor Rated Power
0.00–655.35 kW
#.##
○
○
05-03 Motor Rated Speed
(rpm)
0–65535 1710
○
○
○
05-04 Number of Motor Poles 2–48
4
○
○
○
○
05-05 Motor No-load Current 0–Pr.05-01 <default>
#.##
○
○
○
05-06 Motor Rs
0.000–65.535
0.000
○
○
05-07 Motor Rr
0.000–65.535
0.000
○
○
05-08 Motor Lm
0.0–6553.5 mH
0.0
○
○
05-09 Motor Lx
0.0–6553.5 mH
0.0
○
○
05-10 Torque Compensation
Low Pass Filter Time
0.001–10.000 sec.
0.020
○
05-11 Slip Compensation Low
Pass Filter Time
0.001–10.000 sec.
0.100
○
05-12 Torque Compensation
Gain
0–10 0
○
○
05-13 Slip Compensation Gain 0.00–10.00
1.00
○
05-14 Slip Deviation Level
0–1000% (0: disable)
0
○
○
○
05-15 Slip Deviation Detection
Time
0.0–10.0 sec.
1.0
○
○
○
05-16
Over-slip Action
0: Warn and keep operation
1: Fault and ramp to stop
2: Fault and coast to stop
0
○
○
○
05-17 Hunting Gain
0–10000 (0: disable)
2000
○
○
○
05-18 Accumulated Motor
Operation Time (Min.)
0–1439 0
○
○
○
○
○
05-19 Accumulated Motor
Operation Time (day)
0–65535 0
○
○
○
○
○
05-20 Core Loss
Compensation
0–250% 10
○
05-21 Accumulated Motor
Power-on Time (Min.)
0–1439 0
○
○
○
○
○
05-22 Accumulated Motor
Power-on Time (day)
0–65535 0
○
○
○
○
○
05-23 Slip Compensation Gain
% (Power Generation
Mode)
0.0–100.0% 0.0
○
○
05-24 Slip Compensation Gain
% (Electricity Mode)
0.0–100.0% 0.0
○
○
Summary of Contents for VFD-ED Series
Page 3: ......
Page 10: ...Ch01 Introduction VFD ED 1 3 1 2 Model Name 1 3 Serial Number...
Page 21: ...Ch01 Introduction VFD ED 1 14 Built In Keyboard Panel KPED LE01 Unit mm inch...
Page 26: ...Ch02 Installation VFD ED 2 5 Ambient Temperature Derating Curve Altitude Derating Curve...
Page 27: ...Ch02 Installation VFD ED 2 6 The page intentionally left blank...
Page 28: ...Ch03 Wiring VFD ED 3 1 Chapter 3 Wiring 3 1 Wiring 3 2 System Wiring Diagram...
Page 30: ...Ch03 Wiring VFD ED 3 3 3 1 Wiring...
Page 32: ...Ch03 Wiring VFD ED 3 5...
Page 38: ...Ch04 Main Circuit Terminals VFD ED 4 3 4 1 Main Circuit Diagram Frame B Frames C D Frame E...
Page 46: ...Ch05 Control Terminals VFD ED 5 3 Frame E Step 1 Step 2 Step 3...
Page 47: ...Ch05 Control Terminals VFD ED 5 4 5 2 Control Terminal Specifications...
Page 51: ...Ch05 Control Terminals VFD ED 5 8 The page intentionally left blank...
Page 94: ...06 Optional Accessories VFD ED 6 43 EMC Filter Model B84143D0150R127 Unit mm inch...
Page 95: ...06 Optional Accessories VFD ED 6 44 EMC Filter Model B84143D0200R127 Unit mm inch...
Page 96: ...06 Optional Accessories VFD ED 6 45 EMC Filter Model B84142A0042R122 Unit mm inch...
Page 242: ...Ch12 Descriptions of Parameter Settings VFD ED 12 31 Elevator Timing Diagram...
Page 313: ...Ch12 Descriptions of Parameter Settings VFD ED 12 102 The page intentionally left blank...
Page 317: ...Ch13 Warning Codes VFD ED 13 4 The page intentionally left blank...
Page 329: ...Ch14 Fault Codes VFD ED 14 12 The page intentionally left blank...
Page 351: ...Ch16 Safe Torque Off Function VFD ED 16 10 16 5 6 STL1 Figure 6 16 5 7 STL2 Figure 7...
Page 353: ...Ch16 Safe Torque Off Function VFD ED 16 12 The page intentionally left blank...
Page 373: ...Appendix A EMC Standard Installation Guide VFD ED A 20 The page intentionally left blank...
Page 389: ...Appendix B Revision History VFD ED B 16 The page intentionally left blank...