Delem
V1101, 3.46
Parameter 46:
Closing brake ramp trim
Range
: -2.0 - +2.0
Default
:
0.0
Units
:
-
Function
To adjust the ramp to brake the beam from the fast closing phase to mute.
Description
For large machines it is sometimes desired to adjust (or trim) the brake ramp during closing.
Figure 46.a
The recommended way to adjust this parameter
•
Program the closing speed lower or equal to the hydraulic closing speed.
•
Program machine parameter 32 (closing ramp offset) to 0 (zero).
•
Set the machine to ‘adjust’ mode (hand input active).
•
Adjust parameter 46 until you get a smooth stop of the beam at the mute point.
•
Program then machineparameter 32 to a value that the beam stops about 0.5 - 1 mm lower
than the programmed mute position.
Note
This parameter is related to machine parameter 47 (= gain trim for closing movement),
increasing this parameter will also result in steeper braking and vice versa.
Summary of Contents for DA-65
Page 1: ...Delem V0303 MACHINE PARAMETERS MANUAL DA 65 V7 DA 69 V7 DA 68PL V7 DA on Windows V1...
Page 17: ...Delem V1101 1 6...
Page 55: ...Delem V1101 3 16 Parameter 16 19 Not used...
Page 67: ...Delem V1101 3 28 Parameter 28 Not used...
Page 68: ...Delem V1101 3 29 Parameter 29 Not used...
Page 79: ...Delem V1101 3 40 Parameter 40 41 Not used...
Page 81: ...Delem V1101 3 43 Parameter 43 45 Not used...
Page 89: ...Delem V1101 3 53 Parameter 53 Not used...
Page 94: ...Delem V1101 3 58 Parameter 58 Not used...
Page 96: ...Delem V1101 3 60 Parameter 60 119 Not used...
Page 175: ...Delem V1101 6 5 6 4 Crowning parameters Figure 6 4 a...
Page 197: ...Delem V1101 8 3 8 3 Digital I axis parameters Figure 8 3 a...
Page 207: ...Delem V1101 9 5 Figure 9 2 c Figure 9 2 d...
Page 239: ......