Delem
V1101, 5.22
Parameter 27:
Correction (X)
Range
: -9.999 - +9.999
Default
:
0.000
Units
: mm / 100mm
Remark
: In case of a Z1- and Z2-axis, only in combination with a X1-axis and a X2-axis.
Function
To compensate for mechanical deviations during X-axis movements.
Description
When the X-axis moves to another position it is possible that the Z1Z2-axis position changes.
You can use this parameter to program a position correction.
See figure 4.2k how to program the parameter. Notice the sign of the parameter value!
Correction (X) = measured value - programmed value
Example
= 135 mm - 140 mm = 5
mm / 50 mm
= 10 mm / 100 mm
Figure 5.2.d